DTS-A004 4-in-1 Fixed Gas Detector

The four-in-one gas detector is a new type of gas detector produced by our company. It adopts a sensor moduleization scheme without the need for calibration. The product settings are stored in the module, which is convenient for replacement and after-sales maintenance.

Detection Principle Semiconductor, catalytic combustion, electrochemical, infrared, PID
Sampling Method Natural diffusion
Display Method High-brightness red digital tube

Product Introduction

The four-in-one gas detector is a new type of gas detector produced by our company. It adopts a sensor moduleization scheme without the need for calibration. The product settings are stored in the module, which is convenient for replacement and after-sales maintenance. It has excellent repeatability and temperature/humidity characteristics, a long service life, and is easy to operate. It is suitable for detecting gas concentrations in industrial environments.

The four-in-one gas detector converts the signal of the gas concentration to be detected in the air into a digital signal for display. It uses a three-wire 4-20mA current signal and RS485 signal output method. It can be optionally equipped with wireless communication, which is convenient for users to choose.

Product Features

Alarm record query function.
Detection accuracy and Adjustable range.
Long life, high sensitivity, low drift, stable and reliable work.
Sensor failure self-test, two-level concentration alarm, with relay output function.
Digital display of gas concentration and working status. Temperature compensation, automatic zero correction function.
4- 20mA standard analog output and RS485 digital output, which can be uploaded to PLC and DCS system.
Infrared remote control mode, without opening the cover can be adjusted to the detector, safe and convenient.
Adopting explosion-proof design. suitable for hazardous conditions 1. 2 zones.

Technical Specifications

Detection PrincipleSemiconductor, catalytic combustion, electrochemical, infrared, PID
Sampling MethodNatural diffusion
Display MethodHigh-brightness red digital tube
Status Indication4 indicator lights: power, fault, alarm 1, alarm 2
Ambient Temperature-20°C to 50°C
Relative Humidity< 95% RH
Explosion-Proof TypeFlameproof enclosure
Explosion-Proof RatingEx d IIC T6 Gb
Power SupplyDC 24 V ± 30%
Output SignalCurrent: 4–20 mA; switching output: 2 channels
Adjustment MethodInfrared remote control
Power Consumption≤ 3 W
Cable Requirements≥ 1.5 mm² shielded cable
Max. Distance Between Detector and Host≤ 1000 m
Weight≤ 2000 g
Pressure Range86–106 kPa

Application Fields

The four-in-one gas detector is applicable to industrial sites where toxic gases exist, such as power plants, oil refineries, chemical plants, liquefied gas stations, gas boiler rooms, gas filling stations, spray painting rooms, etc., for gas safety detection and alarm.

Measurable Gas

tracer gasrangeAlarm valueleast countresponse time
combustible gas (EX)0-100%LEL20%LEL1%LEL≤ 10 seconds
oxygen (O2)0-30%VOL19.5%Vol0.1%Vol≤ 15 seconds
carbon monoxide(CO)0-1000ppm50ppm1ppm≤25 seconds
carbon dioxide (CO2)0-5%VOL0.2%VOL0.01%VOL≤30 seconds
formaldehyde (CH2O)0-50ppm10ppm0.1ppm≤ 40 seconds
ozone (O3)0-20ppm5ppm0.1ppm≤30 seconds
Hydrogen sulfide(H2S)0-100ppm15ppm1ppm≤ 30 seconds
sulfur dioxide (SO2)0-20ppm5ppm0.1ppm≤ 30 seconds
nitric oxide (NO)0-250ppm20ppm1ppm≤60 seconds
nitrogen dioxide(NO2)0-20ppm5ppm0.1ppm≤ 60 seconds
nitrogen oxide (NOX)0-100ppm20ppm1ppm≤ 60 seconds
chlorine gas(CL2)0-20ppm5ppm0.1ppm≤ 60 seconds
ammonia gas(NH3)0-100ppm15ppm0.1ppm≤60 seconds
hydrogen (H2)0-1000ppm50ppm1ppm≤ 60 seconds
hydrogen cyanide(HCN)0-20ppm2ppm0.1ppm≤ 60 seconds
Hydrogenchloride(HCL)0-50ppm5ppm0.1ppm≤60 seconds
 Phosphine(PH3)0-20ppm2ppm0.1ppm≤ 60 seconds
Ethylene oxide (ETO)0-100ppm20ppm1ppm≤120 Seconds
phosgene (COCL2)0-100ppm5ppm1ppm≤ 60 seconds
silane (SiH4)0-50ppm10ppm0.1ppm≤ 60 seconds
Fluoride (F2)0-20ppm5ppm0.1ppm≤ 30 seconds
hydrogen fluoride(HF)0-20ppm5ppm0.1ppm≤30 seconds
bromine hydride(HBr)0-50ppm10ppm0.1ppm≤60 seconds
arsenic hydride(AsH3)0-20ppm1ppm0.1ppm≤ 30 seconds
Hydrazine, hydrazine(N2H4)0-100ppm20ppm1ppm≤ 60 seconds
Tetrahydrothiophene(THT)0-100mg/m320mg/m31mg/m3≤ 60 seconds
Bromine (BR2)0-20ppm5ppm0.1ppm≤ 60 seconds
ethyne (C2H2)0-100%LEL20%LEL1%LEL≤60 seconds
ethylene (C2H4)0-100%LEL20%LEL1%LEL≤ 60 seconds
alcohol (C2H6O)0-100%LEL20%LEL1%LEL≤30 seconds
carbinol (CH4O)0-100%LEL20%LEL1%LEL≤30 seconds
carbon disulfide (SC2)0-50ppm10ppm0.1ppm≤120 Seconds
acrylonitrile (C3H3N)0-50ppm10ppm0.1ppm≤60 seconds
aminomethane(CH5N)0-50ppm10ppm0.1ppm≤60 seconds
styrene (C8H8)0-100ppm20ppm1ppm≤30 seconds
chlorylene (C2HCL3)0-50ppm20ppm0.1ppm≤ 60 seconds
Celfume (CH3Br)0-100ppm20ppm1ppm≤30 seconds
benzene (C6H6)0-100ppm20ppm1ppm≤ 30 seconds
methylbenzene(C7H8)0-100ppm20ppm1ppm≤ 30 seconds
dimethylbenzene(C8H10)0-100ppm20ppm1ppm≤30 seconds
Sulfur hexafluoride(SF6)0-100ppm20ppm1ppm≤30 seconds
VOC/TVOC0-1000ppm50ppm1ppm≤ 30 seconds
Laughing gas (N2O)0-100ppm20ppm0.01ppm≤ 30 seconds
argon (Ar)0-100%vol20%Vol1vol≤ 30 seconds

Table of Contents

    Questions or Concerns?
    Let Us Know!

    Please feel free to submit your inquiry to us. our sales engineers will contact you in short time.

    Gas Safety One-stop Solution Provider

    For Customers
    Have a question or need technical support?
    Whether you’re looking for product information, pricing, or a customized gas solution, our team is here to help. Please fill out the form below or reach out to us directly — we’ll get back to you as soon as possible.
    For Distributors & Agents
    Interested in becoming a DUOTESI partner?
    DUOTESI  is actively seeking regional distributors and agents with experience in Gas sensor,Gas detector OEM /ODM , or related technologies. If you’re looking to DUOTESI gas products in your local market, we’d love to hear from you. Let’s explore opportunities to grow together.

    Get In Touch With Us

    *
    Applications:
    Products:
    *